Phoenix VAL-SEC-T2-3S-350-FM Type 2 SPD 3P

3 In stock
SKU
2905340
Quick Overview
Plug-in surge arrester, in accordance with Type 2/Class II, for 3-phase power supply networks with separate N and PE (5-conductor system: L1, L2, L3, N, PE), with remote indication contact.
€300.33 €244.17

Shipping Information

Free Shipping - On Orders Over €150.

Money Back Guarantee.

Ships Items Quickly.

Product properties
IEC test classificationII
T2
EN typeT2
IEC power supply systemTN-S
TT
TypeDIN rail module, two-section, divisible
Product typeSurge arrester
Number of positions4
Surge protection fault messageOptical, remote indicator contact
Insulation characteristics
Overvoltage categoryIII
Pollution degree2
Electrical properties
Nominal frequency fN50 Hz (60 Hz)
Indicator/remote signaling
Connection nameRemote fault indicator contact
Switching functionChangeover contact
Operating voltage5 V AC ... 250 V AC
125 V DC (200 mA DC)
Operating current5 mA AC ... 1 A AC
1 A DC (30 V DC)
Connection data
Connection methodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible2.5 mm² ... 16 mm²
Conductor cross section solid2.5 mm² ... 25 mm²
Conductor cross section AWG12 ... 4
Connection methodFork-type cable lug
Conductor cross section flexible1.5 mm² ... 6 mm²
Dimensions
Width49.2 mm
Height97.9 mm
Depth74.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch2.7 Div.
Material specifications
Colorlight grey RAL 7035
traffic grey A RAL 7042
Flammability rating according to UL 94V-0
CTI value of material600
Insulating materialPA6.6-FR 20% GF
PBT-FR
Material groupI
Housing materialPA 6.6-FR 20 % GF
PBT-FR
Protective circuit
Mode of protectionL-N
L-PE
N-PE
Direction of action3L-N & N-PE
Nominal voltage UN240/415 V AC (TN-S)
240/415 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC (L-N)350 V AC
Maximum continuous operating voltage UC (L-PE)350 V AC
Maximum continuous operating voltage UC (N-PE)264 V AC
Rated load current IL40 A (Biconnect M4 fork-type cable lug 6​ mm²)
63 A (TWIN ferrule 2 x 10 mm²)
Residual current IPE≤ 1 µA
Nominal discharge current In (8/20) µs20 kA
Maximum discharge current Imax (8/20) µs40 kA
Follow current interrupt rating Ifi (N-PE)100 A (264 V AC)
Short-circuit current rating ISCCR25 kA (for a backup fuse of up to 315 A gG)
50 kA (for a backup fuse of up to 200 A gG)
Voltage protection level Up (L-N)≤ 1.5 kV
Voltage protection level Up (L-PE)≤ 1.9 kV
Voltage protection level Up (N-PE)≤ 1.5 kV
Residual voltage Ures (L-N)≤ 1.5 kV (at In)
≤ 1.3 kV (at 10 kA)
≤ 1.2 kV (at 5 kA)
≤ 1.1 kV (at 4 kA)
≤ 1 kV (at 2 kA)
Residual voltage Ures (L-PE)≤ 1.9 kV (at In)
≤ 1.5 kV (at 10 kA)
≤ 1.4 kV (at 5 kA)
≤ 1.3 kV (at 4 kA)
≤ 1.2 kV (at 2 kA)
Residual voltage Ures (N-PE)≤ 0.5 kV (at In)
≤ 0.5 kV (at 10 kA)
≤ 0.5 kV (at 5 kA)
≤ 0.5 kV (at 4 kA)
≤ 0.5 kV (at 2 kA)
TOV behavior at UT (L-N)415 V AC (5 s / withstand mode)
457 V AC (120 min / safe failure mode)
TOV behavior at UT (N-PE)1200 V AC (200 ms / withstand mode)
Response time tA (L-N)≤ 25 ns
Response time tA (L-PE)≤ 100 ns
Response time tA (N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)
63 A (gG / TWIN ferrule 2x 10mm²)
Max. backup fuse with branch wiring315 A (gG)
Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
Approval data
UL specifications
Maximum continuous operating voltage MCOV (L-L)700 V AC
Maximum continuous operating voltage MCOV (L-N)350 V AC
Maximum continuous operating voltage MCOV (L-G)350 V AC
Maximum continuous operating voltage MCOV (N-G)264 V AC
Nominal discharge current In (L-L)20 kA
Nominal discharge current In (L-N)20 kA
Nominal discharge current In (L-G)20 kA
Nominal discharge current In (N-G)20 kA
Mode of protectionL-L
L-N
L-G
N-G
Nominal voltage240/415 V AC
Power distribution systemWye
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-L)3280 V
Measured limiting voltage MLV (L-N)2000 V
Measured limiting voltage MLV (L-G)2080 V
Measured limiting voltage MLV (N-G)950 V
Follow current (L-G)200 A (264 V AC)
SPD Type4CA
AC operating voltage125 V AC
AC operating current1 A AC
UL connection data
Tightening torque40 lbf-in. ... 50 lbf-in.
Conductor cross section AWG14 ... 2 (solid)
14 ... 4 (flexible)
Standards and regulations
Standards/specificationsIEC 61643-11
Standards/specificationsEN 61643-11
Mounting
Mounting typeDIN rail: 35 mm